Linthal spinning mill - Replacement of pressure line
Scope of services / technical features
Our services included complete technical processing, design, static calculations, drafting of the workshop plans, material acquisition, manufacture, corrosion protection, transport and assembly including fill test and acceptance of the pressure line.
Key specifications
Length of the pressure line
Ltot
544m
Constant diameter
Da
457mm
Wall thickness
s
6.3 and 8.0mm
Material quality
ST 37.0 and St 52.0 with 3.1 Attest
Static pressure height
H stat.
431.5 mWs
Dynamic pressure surge
H dyn.
86.3 mWS of this corresponded to 20% of H stat.
Max. calculation pressure
pi
51.8 bar (central)
Brief description
Complete renovation of the compressed water line with constant pressure measurement DN450 and flange connections. The flange pipes were manufactured at the factory and transported to the construction site using a lorry. The assembly work includes the assembly of the old as well as assembly of the new line in the tunnel. Transport to the construction site was carried out by railroad transport cars which we designed and built ourselves.